<LOGO>
FM Transmitter Measurement Report
Created: 2026-01-18 14-44-22
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
89.40 MHz 5/5, 44 dBuV ISKELMA
Pilot RDS Phase Difference
6.4 kHz 3.7 kHz -84 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 70 kHz 19139 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
5,1 dBr 5,92 dBr 6,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ISKELMA " 62AD 9 (Varied) 1 0 1 1 --:--
RT
-
AF EON
89.4, 92.5, 95.0, 100.1 MHz -
FM Scope Max at: 70 kHz MIN: 13 kHz % above 76 kHz: 0,0000 Acquired: 2026/01/18 14.43.17 Total samples: 19139 Equivalent time: 0:15:56 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 6,5 dBr MIN: 5,1 dBr AVE: 5,92 dBr % above 12,2 dBr: 0,0 Last value: 6,4 dBr (2026/01/18 14.43.16) 14.30 14.32 14.34 14.36 14.38 14.40 14.42 0 2 4 6 Pm [dBr]